Futek CSG110 (JM-2A / JM-2AD)-Series Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 11
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
- 8 -
Tel: (949) 465-0900
Fax: (949) 465-0905
Toll Free: (800) 23 FUTEK
1 UP 0.5 5 UP 2.5
DOWN N/ A DOWN N/ A
2 UP 1 6 UP 3
DOWN N/ A DOWN N/ A
3 UP 1.5 7 UP 4
DOWN N/ A DOWN N/ A
4 UP 2 8 UP 10
DOWN N/ A DOWN N/ A
SW3: Sensitivity (mV/V)
Bandwidth
There are two bandwidth settings available on the CSG110: 1 kHz (default), and 10 kHz.
To select the bandwidth, simply flip the DIP switch to the appropriate configuration.
Ex. If your application requires a higher bandwidth in order to account for the higher
frequency signals, such as those from dynamic applications, then you would want to
use the higher setting bandwidth.
UP
10
(3)
DOWN 1
SW4: Bandwidth
Current Setting
(4)
There are four current output settings available on the CSG110: 0-16 mA, 0-20 mA, 4-20
mA (default), and 5-25 mA. To select the current, simply flip the DIP switches to the
appropriate configuration.
SW5 SW6 SW7 Input Range (V)
Output Range (mA)
DOWN DOWN DOWN 0-10 4-20
DOWN DOWN UP 0-10 5-25
UP DOWN DOWN 0-10 0-16
UP DOWN UP 0-10 0-20
DOWN UP DOWN 0-5 4-20
DOWN UP UP 0-5 5-25
UP UP DOWN 0-5 0-16
UP UP UP 0-5 0-20
Note: Only available with current output option.
(3) 25 kHz for QSH01498
(4) Only available with current output option
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11

Comentarios a estos manuales

Sin comentarios