- 6 -
Tel: (949) 465-0900
Fax: (949) 465-0905
Toll Free: (800) 23 FUTEK
shunt
excitation
polarity
bandwidth
gain
SW1
SW2
SW4
SW5
current setting
SW8
SW6
current input range
SW7
SW3
Excitation
There are two excitation values available on the CSG110: 10 VDC (default), and 5 VDC.
To select the excitation, simply flip the DIP switch to the appropriate configuration.
The excitation voltage controls the maximum output of the amplifier.
Ex. If your application requires a lower output voltage than 10 VDC, then the 5 VDC
option is available to use. All you have to do is flip the DIP switch from the down
position to the up position.
Polarity
There are two polarities available on the CSG110: reverse, and straight (default). To
select the polarity, simply flip the DIP switch to the appropriate configuration.