12 EM1005
4.2. Plug Connection (12 pin)
Top View Built-In Plug
* Torque and Angle share the same pin for Ground.
4.2.1. Installing the Signal Lead
Do not run the lead parallel to power cables or
control
circuits.
Do not place the
l
ead
close to
equipment
p
roducing
strong
electromagnetic
fields, such as,
transformers,
welders,
contactors,
electric
motors,
etc.
If such situations cannot be avoided, run
the lead
i
ns
id
e
earthed steel
conduit.
Make a loop in the
l
ead
when a ffixing it at the
torque
sensor so that it is not
damaged
by
vibration.
If supply and evaluation unit are galvanically
connected,
a
differential input must be
used for the torque signal
to
prevent the voltage drop on the power supply ground
affecting the
torque output
sign
al.
Function
Pin
Torque
, Power Supply
F
Torque
, Power Supply, Ground
*E
Torque
, Signal Output
C
Torque
, Signal Output, Ground D
Angle
, Power Supply H
Angle
, Power Supply, Ground *E
Angle 1/ Speed
, Signal Output B
Angle 2 (90° shifted to Angle 2)
, Signal Output
G
Shunt Calibration
, Power Supply
K
Shunt Calibration
, Power Supply, Ground
A
Shield
, Inside the sensor to housing
M
Not Connected
J
Not Connected
L